ADA Single-User Restroom Layout
9'-2 3⁄8" × 7'-0" Interior Clear — Submission-Ready Architectural Floor Plan • Vector (SVG)
Print this page at 11"×17" (ANSI B / Tabloid) in landscape with “Fit to Page” OFF and margins set to 0.25" for scale-accurate output at 1/4" = 1'-0".
GENERAL NOTES
- All dimensions are to the interior face of finished wall unless noted otherwise. Wall construction: 2×4 wood stud @ 16" O.C. with ½" GWB each side (5" total).
- Toilet centerline: 18" from side wall per 2010 ADA Standards / ICC A117.1 §604.2.
- Toilet clearance: 60" × 59" for floor-mounted water closet per §604.3.1.
- Grab bars: stainless steel, 1¼"–1½" Ø, mounted at 33–36" AFF. Rear bar 36" min (§604.5.2); side bar 42" min (§604.5.1). Blocking in wall required.
- Lavatory: wall-mounted with knee clearance 27" min AFF. Clear floor space 30"×48" forward approach (§606.2).
- Mirror: bottom edge of reflecting surface at 40" max AFF (§603.3).
- Door: 36" leaf providing 32" min. clear opening; swings outward; lever hardware, max 5 lbf operating force (§603.2.3, §404.2.9).
- 60" Ø turning space may overlap fixture clearance zones per §603.2.1.
- Floor: non-slip finish, static COF ≥ 0.60 wet per ADA advisory.
- Ceiling height: 8'-0" AFF minimum. Exhaust fan per local mechanical code.
- DIMENSIONS GOVERN over graphic scale. Verify all dimensions in field prior to construction.
- 9'-2 3/8" = 110.375" = 9.198' ≈ 9.2' (difference: 0.025", within construction tolerance).
- This plan depicts layout and ADA compliance only. Separate MEP (mechanical, electrical, plumbing) drawings may be required by the AHJ.
ADA / ICC A117.1-2017 Code Reference ▼
§603.2.1 Turning Space: 60" diameter circle or T-shaped turning space required in all single-user toilet rooms.
§604.2 Water Closet Location: Centerline 16–18" from side wall or partition.
§604.3 Clearance: 60" min width. Depth: 56" min (wall-hung) or 59" min (floor-mounted).
§604.5 Grab Bars: Side bar: 42" min long, 12" max from rear wall. Rear bar: 36" min long. All mounted 33–36" AFF to centerline.
§606 Lavatories: Rim max 34" AFF. Knee clearance 27" min AFF, 8" deep min at 27". Clear floor 30"×48" forward approach.
§603.3 Mirrors: Bottom edge of reflecting surface max 40" AFF (above lavatories) or full-length.
§603.2.3 Door Swing: Shall not swing into required clear floor space of any fixture. Outward swing required for single-user rooms.
§404.2.9 Door Hardware: Operable with one hand, no tight grasping/pinching/twisting. Max 5 lbf.